| Ordering Information - ASR 902 System Components |
|---|
| ASR-902 | ASR 902 Router Chassis |
| ASR-902= | ASR 902 Router Chassis, Spare |
| A902-FAN-E | ASR 902 Enhanced FAN Tray with FAN Filter Slot |
| A902-FAN-E= | ASR 902 Enhanced FAN Tray with FAN Filter Slot, Spare |
| A902-FAN-F | ASR 902 FAN Tray Filter |
| A902-FAN-F= | ASR 902 FAN Tray Filter, Spare |
| A902-FAN-F-B= | ASR 902 FAN Tray Filter Blank Panel, Spare |
| A902-CAB-BRACKET= | ASR 902 Cable Guide Bracket, Spare |
| A902-RCKMNT-ETSI= | ETSI Rack Mount Option for the Cisco ASR 902, Spare |
| A902-RCKMNT-19IN= | EIA 19in Rack Mount Option for the Cisco ASR 902, Spare |
| Ordering Information - ASR 903 System Components |
|---|
| ASR-903 | ASR 903 Router Chassis |
| ASR-903= | ASR 903 Router Chassis, Spare |
| A903-FAN | ASR 903 FAN Tray |
| A903-FAN= | ASR 903 FAN Tray, Spare |
| A903-FAN-E | ASR 903 Enhanced FAN Tray with FAN Filter Slot |
| A903-FAN-E= | ASR 903 Enhanced FAN Tray with FAN Filter Slot, Spare |
| A903-FAN-F | ASR 903 FAN Tray Filter |
| A903-FAN-F= | ASR 903 FAN Tray Filter, Spare |
| A903-FAN-F-B= | ASR 903 FAN Tray Filter Blank Panel, Spare |
| A903-RCKMNT-ETSI= | ETSI Rack Mount Option for the Cisco ASR 903, Spare |
| A903-RCKMNT-19IN= | EIA 19in Rack Mount Option for the Cisco ASR 903, Spare |
| A903-CAB-GUIDE= | ASR 903 Cable Guide Bracket, Spare |
| A903-CAB-BRACKET= | ASR 903 Cable Guide Bracket Option, Spare |
| Ordering Information - ASR 907 System Components |
|---|
| ASR-907 | ASR 907 Router Chassis |
| ASR-907= | ASR 907 Router Chassis, Spare |
| A907-FAN-E | ASR 907 Enhanced FAN Tray with FAN Filter Slot |
| A907-FAN-E= | ASR 907 Enhanced FAN Tray with FAN Filter Slot, Spare |
| A907-FAN-F= | ASR 907 FAN Tray Filter, Spare |
| A907-FAN-F-B= | ASR 907 FAN Tray Filter Blank Panel, Spare |
| A907-RCKMNT-ETSI= | ETSI Rack Mount Option for the Cisco ASR 907, Spare |
| A907-RCKMNT-19IN= | EIA 19in Rack Mount Option for the Cisco ASR 907, Spare |
| A907-CAB-BRACKET= | ASR 907 Cable Guide Bracket, Spare |
| Ordering Information - ASR 900 Common Equipment |
|---|
| A900-PWR550-A | ASR 900 550W AC Power Supply |
| A900-PWR550-A= | ASR 900 550W AC Power Supply, Spare |
| A900-PWR550-D-E | ASR 900 550W DC Power Supply With Enhanced Power Connector |
| A900-PWR550-D-E= | ASR 900 550W DC Power Supply With Enhanced Power Connector, Spare |
| A900-PWR1200-A | ASR 900 1200W AC Power Supply |
| A900-PWR1200-A= | ASR 900 1200W AC Power Supply, Spare |
| A900-PWR1200-D | ASR 900 1200W DC Power Supply |
| A900-PWR1200-D= | ASR 900 1200W DC Power Supply, Spare |
| A900-PWR-BLANK= | ASR 900 Power Supply Blank Cover, Spare |
| A900-RSPA-BLANK= | ASR 900 Route Switch Processor Type-A Blank Cover, Spare |
| A9XX-RSPB-BLANK= | ASR 900 Route Switch Processor Type-B Blank Cover, Spare |
| A900-IMA-BLANK= | ASR 900 Interface Module Type-A Blank Cover, Spare |
| A900-IMA-BLNK-DEF= | ASR 900 Interface Module Type-A Blank Cover with deflector, Spare |
| System Specifications - Cisco ASR 907/914 Router (Relevant to Fan Tray) |
|---|
| Physical Specifications Height | 12.22 in. (310.38 mm) - 7RU |
| Physical Specifications Width | 17.44 in. (443 mm) |
| Physical Specifications Depth | 9.22 in. (234.2 mm) |
| Weight Fully Loaded | 69.32 lb (31.4 kg) with two RSPs, two DC power supplies, and loaded with a typical combination of interface module cards |
| Weight Empty Chassis | 34.9 lb (15.9 kg) |
| Rack Mounts | ETSI rack mount kit, 19 in. rack mount kit, 23 in. rack mount kit |
| Power Supply Slots | 3 power supply slots |
| Interface Module Slots | 16 interface module slots |
| Route Switch Processor Slots | 2 RSP slots |
| Fan Tray | 1 fan tray with fan redundancy, 4 dry contact input alarms on the fan tray |
| Air Flow | Side-to-side airflow; inlet on the right side, outlet on the left side when looking from the front |
| Chassis MTBF at 40ºC | 1,585,000 hours |
| Fan Tray MTBF at 40ºC | 1,329,000 hours |
| Power Specifications |
|---|
| Maximum Input Power | 1350W (including loss). This is equivalent to 4600 BTU per hr. Typical input power depends on the actual configuration |
| AC Input Voltage and Frequency | Voltage range: 85 to 264 VAC, nominal 115 to 230 VAC; Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz |
| AC Power Supply MTBF at 40ºC | 300,000 hours |
| DC Input Voltage | For 550W DC power supply, voltage range: 19.2V to 72V DC, nominal +24V DC, -48V/–60V DC. For 1200W DC power supply, voltage range: –40.8V to –72V DC, nominal –48V/–60V DC |
| DC Power Supply MTBF at 40ºC | 300,000 hours |
| Power Supply Shipment Packaging Size (LxWxH) | 15.44 in. x 9.44 in. x 4.31 in. |
| Power Supply Shipment Weight | 3.6 lbs. |
| Environmental Specifications |
|---|
| Operating Environment and Altitude | –40 to 65ºC operating temperature (DC operation, with both the 550W and the 1200W power supplies); –40 to 65ºC operating temperature (AC operation, with the 1200W power supply); –5 to 55ºC operating temperature (AC operation, with 550W AC power supply); 0 to 40ºC operating temperature (AC operation, with 550W AC power supply); –60 to 1800m operating altitude (for full operating temperature range); Up to 4000m operating altitude (at up to 40ºC temperature) |
| Outside Plant | For an outside plant installation, it is required that the router be protected against airborne contaminants, dust, moisture, insects, pests, corrosive gases, polluted air, or other reactive elements present in the outside air. To achieve this level of protection, it is recommended that the unit be installed in a fully sealed enclosure. Examples of such cabinets include IP65 cabinets with heat exchanger complying with Telecordia GR487. |
| Relative Humidity | 5 to 95%, noncondensing |
| Acoustic Noise | Acoustic noise peak operation complies with Network Equipment Building Standards (NEBS) GR-63-Core Issue 3 sound power level of 78 dB at 27ºC operation as measured by the ANSI S12.10/ISO 7779 NAIS noise measurement test standard. |
| Storage Environment | Temperature: –40 to 70ºC; altitude: 15,000 ft (4570m) |
| Seismic | Zone 4 |
| Hazardous Substances | Reduction of Hazardous Substances (ROHS) 6 |
| Safety and Compliance |
|---|
| Safety Standards | UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1-07 2nd edition; IEC 60950-1, 2nd edition; EN 60950-1, 2nd edition; AS/NZS 60950.1:2003 |
| Electromagnetic Emissions Compliance | FCC CFR47 Part 15 Class A; EN55022, class A; CISPR22, class A; ICES-003, class A; EN 300 386, class A; VCCI, class A; KN22, class A; EN61000-3-2 to EN61000-3-3 |
| Immunity Compliance | EN 300 386; EN 61000-6-1; EN 50082-1; CISPR24; EN 55024; KN 24; EN 50121-4; EN/KN 61000-4-2 to EN/KN 61000-4-6; EN/KN 61000-4-8; EN/KN 61000-4-11 |
| Power Substation System Compliance | IEC-61850-3 (2002) (Cisco ASR 903); IEEE1613 (2009) (Cisco ASR 903); IEC 60870-2-2 Am Class (Cisco ASR 907) and IEC 60870-2-2 Bm Class (Cisco ASR 902 / Cisco ASR 903) |
| NEBS | GR-63-CORE Issue 3; GR-1089-CORE Issue 5; SR-3580 NEBS Level 3 |
| ETSI | ETS/EN 300 119 Part 4; ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2; ETS/EN 300 753 |
| Network Synchronization | ANSI T1.101; GR-1244-CORE; GR-253-CORE; ITU-T G.703 clause 5; ITU-T G.703 clause 9; ITU-T G.781; ITU-T G.813; ITU-T G.823; ITU-T G.824; ITU-T G.8261/Y.1361; ITU-T G.8262; ITU-T G.8264; IEEE1588-2008 |
| Certifications |
|---|
| Common Criteria | Cisco ASR 902 Router and Cisco ASR 903 Router running Cisco IOS XE Software 3.13(1)S |
| FIPS | FIPS 140 validated cryptographic module, Cisco ASR 902 Router and Cisco ASR 903 Router running Cisco IOS XE Software 3.13(1)S |
| MEF | Carrier Ethernet (CE) 1.0 and CE 2.0. MEF 9 and MEF 14 |
| IEEE 1588-2008 | 1588TM SLAVE (IEEE CONFORMITY ASSESSMENT PROGRAM); IEEE 1588TM Conformity Test Suite for Frequency Synchronization in Telecommunications Networks - Packet Slave Clock; IEEE Std 1588TM-2008 and Recommendation ITU-T G.8265.1 (10/2010) with Amendments 1 (04/2011) and 2 (10/2012) |